1-20 of 26
Keywords: gait analysis
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041003.
Published Online: November 14, 2011
.../7279608 6 Davidson , H. M. , 1994 , “ The Isocentric Reciprocating Gait Orthosis ,” APO Newsletter, Sect. 3. 7 Jefferson , R. J. , and Whittle , M. W. , 1990 , “ Performance of Three Walking Orthoses for the Paralysed: A Case Study Using Gait Analysis ,” Prosthet. Orthot...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031010.
Published Online: August 23, 2011
.... 746 – 751 . 11 Bae , J. , Kong , K. , Byl , N. , and Tomizuka , M. , 2009 , “ A Mobile Gait Monitoring System for Gait Analysis ,” in IEEE Proceeding on Rehabilitation Robotics (ICORR) , pp. 73 – 79 . 12 Bae , J. , Kong , K. , Byl , N. , and Tomizuka , M...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031003.
Published Online: July 27, 2011
... gait analysis muscle pneumatic actuators prosthetics Above-knee lower-extremity prosthetics has experienced significant technological advances in recent years, such as the introduction of computer-controlled joint lock–unlock and impedance modulation. Despite the advances, the energetically...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027528.
Published Online: June 14, 2011
...Hildur Einarsdottir 14 06 2011 14 06 2011 gait analysis muscle prosthetics springs (mechanical) POWER KNEE is the world’s first intelligent motor powered prosthetic knee. The knee replaces lost muscle functions and is designed to increase gait symmetry and to reduce...
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. March 2011, 5(1): 011005.
Published Online: March 8, 2011
... biomechanics biomedical measurement bone elastic constants fatigue fatigue testing gait analysis neurophysiology orthopaedics patient treatment prosthetics stress-strain relations viscoelasticity 17 08 2010 13 01 2011 08 03 2011 08 03 2011 2011 American Society...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J. Med. Devices. March 2011, 5(1): 014502.
Published Online: February 17, 2011
... metallic ones. The kits were adapted to four patients and assessed via gait analysis and questionnaire. A very good function is observed, with neither significant difference in most of spatiotemporal gait parameters compared to normal values ( p < 0.05 ) nor significant asymmetries between prosthetic...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. March 2011, 5(1): 011002.
Published Online: February 3, 2011
... , “ Anthropometric Source Book: Volume I: Anthropometry for Designers ,” NASA Reference Publication No. 1024. Angeles , J. , 1997 , Fundamentals of Robotic Mechanical Systems: Theory, Methods, and Algorithms , Springer-Verlag , New York . Perry , J. , 1989 , Observational Gait Analysis...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. September 2010, 4(3): 031004.
Published Online: August 31, 2010
... rehabilitation strategies. falls toe clearance optical sensor wireless motion analysis biomedical optical imaging footwear gait analysis optical sensors 18 01 2010 21 06 2010 31 08 2010 31 08 2010 2010 American Society of Mechanical Engineers ...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027541.
Published Online: August 12, 2010
... concept. After modeling, fabrication, and laboratory testing, a pilot study was conducted in a clinical setting. A simple gait analysis showed asymmetric gait patterns that demonstrated the need for improved swing-phase control and damping, while qualitative feedback indicated the desire to reduce...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027522.
Published Online: August 10, 2010
... force sensors gait analysis hydraulic systems intelligent actuators medical control systems orthotics patient treatment resistors springs (mechanical) 2010 American Society of Mechanical Engineers ...
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027510.
Published Online: August 9, 2010
... material using conventional metal-working machines. The resulting components were lighter and cheaper than equivalent imported metallic ones. The kits were adapted to four patients and assessed via gait analysis. A very good function was observed with no significant differences in spatiotemporal gait...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. June 2010, 4(2): 021004.
Published Online: August 4, 2010
... be employed to develop a customized weight-bearing dynamic orthotic. In addition, the plantar pressure distribution and the trajectory of the center of this pressure distribution are used to design the orthotic. It is shown that the trajectory of the center of pressure, traditionally used in gait analysis...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. March 2010, 4(1): 011003.
Published Online: March 26, 2010
... Technical Manual, Ossur Orthopaedic Products and Services Company, http://www.ossur.com Hitt , J. , 2008 , “ A Robotic Transtibial Prosthesis With Regenerative Kinetics ,” Ph.D. thesis, Arizona State University, Tempe, AZ. Whittle , M. W. , 1996 , Gait Analysis: An Introduction...
Journal Articles
Publisher: ASME
Article Type: Design Innovations
J. Med. Devices. September 2009, 3(3): 035001.
Published Online: August 28, 2009
... high-speed human motion. 18 06 2008 30 07 2009 28 08 2009 accelerometers biological tissues biomechanics biomedical equipment gait analysis muscle motion reaction force sensor accelerometer knee In human dynamic analysis based on measurements...
Journal Articles
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. September 2009, 3(3): 031001.
Published Online: August 28, 2009
... for various medical appliances. 18 03 2008 19 07 2009 28 08 2009 biomechanics biomedical equipment buckling diseases gait analysis patient rehabilitation weight bearing indicator load range indication limb load monitor partial weight bearing Partial weight bearing...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027537.
Published Online: July 9, 2009
... coordinates. 09 07 2009 biomedical ultrasonics gait analysis medical signal processing ultrasound segment's stabilization Goniometry ROM CMS Cartesian coordination 2009 American Society of Mechanical Engineers ...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027509.
Published Online: June 30, 2009
... subjects can interpret this feedback to correct their head pitch and adjust their stride length and gait velocity. 30 06 2009 biomedical equipment biomedical measurement gait analysis patient rehabilitation touch (physiological) vibrations 2009 American Society of Mechanical...
Journal Articles
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027502.
Published Online: June 29, 2009
... energy input. Technical feasibility of the ESO prototype will be evaluated using two subjects with paraplegia. 29 06 2009 biomedical equipment gait analysis handicapped aids wheelchairs 2009 American Society of Mechanical Engineers ...