1-20 of 120
Keywords: biomechanics
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Research-Article
J. Med. Devices. June 2023, 17(2): 021001.
Paper No: MED-21-1241
Published Online: April 17, 2023
... and help mitigate the incidence of falls. balance biomechanics falling perturbation rehabilitation uneven ground Falling is one of the leading causes of both fatal and nonfatal injuries in the United States. In 2017, falling accounted for over 36,000 deaths and 8 million nonfatal visits...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2023, 17(1): 011001.
Paper No: MED-22-1042
Published Online: October 25, 2022
... and relaxing cycle, miming expiration, and inspiration movements during physiological ventilation, Fig. 7 . e-mail:  lucreziapuglisi@hotmail.com e-mail:  marco.ceccarelli@uniroma2.it e-mail:  ambrogi@uniroma2.it 24 03 2022 22 09 2022 25 10 2022 biomechanics rib fixators...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. March 2019, 13(1): 014502.
Paper No: MED-18-1042
Published Online: November 19, 2018
... manuscript received September 12, 2018; published online November 19, 2018. Assoc. Editor: Rafael V. Davalos. 26 02 2018 12 09 2018 finite element analysis needle biopsy biomechanics Needle biopsy is a common minimally invasive procedure to extract tissue samples for diagnosis...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2013, 7(4): 041002.
Paper No: MED-10-1062
Published Online: September 24, 2013
...” ball tip probe may improve assessment of the strength of pedicle screw purchase. bone mineral density assessment screw pull-out strength biomechanics Failure of the pedicle screw at the screw-bone interface is a common clinical problem, particularly in the setting of osteoporosis...
Journal Articles
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2012, 6(4): 045004.
Published Online: November 21, 2012
... in biomaterials, surgical techniques, biomechanics, and tissue engineering provide an opportunity to design a new generation of prosthetic ACL replacements with the goal of improving biocompatibility, mechanical behavior, fixation, and bony integration. The development of a prosthetic ACL device...
Journal Articles
Journal Articles
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041006.
Published Online: November 15, 2011
... to humidity. 21 10 2010 07 10 2011 15 11 2011 15 11 2011 biological tissues biomechanics bioreactors ergonomics micromechanics product development technology management tissue engineering viscoelasticity In the field of tissue engineering, a bioreactor...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2011, 5(4): 044504.
Published Online: November 15, 2011
... systems. 29 03 2011 02 09 2011 15 11 2011 15 11 2011 biomechanics biomembranes cellular biophysics diseases eye geometry physiological models vision Retinal diseases such as age-related macular degeneration, diabetic retinopathy, and retinal vein occlusion (RVO...
Journal Articles
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041004.
Published Online: November 14, 2011
... the clinic. An automatic variable rate device could improve limb lengthening. 06 04 2011 04 10 2011 14 11 2011 biological tissues biomechanics biomedical equipment bone cellular biophysics data loggers orthopaedics real-time systems surgery limb lengthening distraction...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2011, 5(4): 044501.
Published Online: November 7, 2011
... loose due to everyday mechanical demands [( 1 2 3 )]. osteoporosis fractures internal fixation screw peek locking element pull-out biomechanics bone brain medical disorders prosthetics 15 12 2010 10 09 2011 07 11 2011 07 11 2011 References 1...
Journal Articles
Article Type: Design Innovations
J. Med. Devices. September 2011, 5(3): 035001.
Published Online: August 30, 2011
... serve as a simplistic and cost effective alternative for PDA occlusion. 15 04 2010 07 10 2010 30 08 2011 30 08 2011 adhesion biomechanics biomedical electronics biomedical equipment biomedical imaging blood blood vessels cardiology cellular biophysics diseases ducts...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. September 2011, 5(3): 034502.
Published Online: August 18, 2011
... biomechanics biomedical equipment bone drug delivery systems elastic moduli fracture toughness hardness neurophysiology orthopaedics physiological models prosthetics skin microneedle biomicroneedle transdermal drug delivery insertion force Microneedles are micron-scale needles...
Journal Articles
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031006.
Published Online: August 15, 2011
.... The specific design, colored for the three subsystems 19 07 2010 07 06 2011 15 08 2011 15 08 2011 biomechanics biomedical equipment robots A growing number of today’s robots are meant for physical interaction with humans. Humanoid robots shake hands and dual...
Journal Articles
Article Type: Research Papers
J. Med. Devices. September 2011, 5(3): 031005.
Published Online: August 8, 2011
... Perforation with the Variable Stiffness Colonoscope ,” Gastrointest. Endosc. , 57 ( 2 ), pp. 271 – 273 . 10.1067/mge.2003.58 06 12 2010 27 05 2011 08 08 2011 08 08 2011 biological organs biomechanics biomedical education endoscopes force measurement force sensors...
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027536.
Published Online: June 15, 2011
...Rong Fan; Christopher Hobson; Ahmed Bayoumi; John Mayer; William Wagner; Michael S. Sacks 15 06 2011 15 06 2011 biomechanics biomedical materials deformation elasticity finite element analysis haemodynamics medical disorders paediatrics prosthetics surgery tissue...
Journal Articles
Journal Articles
Journal Articles
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027532.
Published Online: June 14, 2011
...Alex Ryan; George Mallin; Paul A. Iaizzo 14 06 2011 14 06 2011 biomechanics cardiovascular system catheters haemodynamics haemorheology In vivo animal models have been and remain the “gold standard” for medical device testing. However, these models sometimes present...