Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-8 of 8
Keywords: stent
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Research-Article
J Biomech Eng. June 2013, 135(6): 061008.
Paper No: BIO-12-1556
Published Online: May 9, 2013
... to primarily occur in the radial direction we modeled materials with isotropy using the transport properties in the radial direction. Mass transport properties were determined for a hydrophobic drug surrogate with transport properties similar to those on drug-eluting stents (e.g., hydrophilicity, lipophilicity...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Briefs
J Biomech Eng. May 2010, 132(5): 054502.
Published Online: March 25, 2010
...C. Marchand; F. Heim; B. Durand Percutaneous aortic valve implantation has become an alternative technique to surgical valve replacement in patients with high risk for surgery. This technique is at its beginning and stents used for valve prostheses remain standard vascular stents. These stents...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Research Papers
J Biomech Eng. June 2009, 131(6): 061006.
Published Online: April 27, 2009
...Nandini Duraiswamy; Richard T. Schoephoerster; James E. Moore, Jr. Four commercially available stent designs (two balloon expandable—Bx Velocity and NIR, and two self-expanding—Wallstent and Aurora) were modeled to compare the near-wall flow characteristics of stented arteries using computational...
Journal Articles
Youngjae Chun, Daniel S. Levi, K. P. Mohanchandra, Fernando Vinuela, Fernando Vinuela, Jr., Gregory P. Carman
Journal:
Journal of Biomechanical Engineering
Article Type: Research Papers
J Biomech Eng. May 2009, 131(5): 051014.
Published Online: April 17, 2009
... sputter deposition. Both stress-strain curves and differential scanning calorimetry curves were generated for the film used to fabricate stents. The films used for stents had an A f temperature of approximately 36°C allowing for body activated response from a microcatheter. The 10 μ m film was only...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Briefs
J Biomech Eng. March 2009, 131(3): 034506.
Published Online: January 7, 2009
... techniques such as PIV increases confidence in such predictions. 08 08 2008 23 09 2008 07 01 2009 biomedical imaging brain convection diffusion haemodynamics intracranial aneurysm stent mathematical modeling convection diffusion time constant kinetic energy...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Research Papers
J Biomech Eng. April 2008, 130(2): 021018.
Published Online: April 4, 2008
...P. Mortier; M. De Beule; S. G. Carlier; R. Van Impe; B. Verhegghe; P. Verdonck Stents are small tubelike structures, implanted in coronary and peripheral arteries to reopen narrowed vessel sections. This endovascular intervention remains suboptimal, as the success rate is limited by restenosis...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Papers
J Biomech Eng. February 2005, 127(1): 25–31.
Published Online: March 8, 2005
...Niels Grabow; Martin Schlun; Katrin Sternberg; Nico Hakansson; Sven Kramer; Klaus-Peter Schmitz Background: The development of endoluminal stents from polymeric materials requires an understanding of the basic mechanical properties of the polymer and the effects of manufacturing and sterilization...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Papers
J Biomech Eng. August 2002, 124(4): 342–346.
Published Online: July 30, 2002
... April 2002 30 07 2002 surgery blood vessels cardiovascular system Angioplasty Bleeding Catheter Closure Complication Device Hematoma Hemorrhage Hemostasis Stent During diagnostic or interventional cardiac catheterization, a femoral
artery is normally...