Due to the transient operation of short duration facilities (0.2–1.0s running time), fidelity in temperature reproduction requires both minimum steady-state errors and a frequency response above 20Hz. Even with the smallest thermocouple wire diameter (∼12μm), badly designed probes may suffer from unsteady heat conduction between wires and supports. The resulting error is often much larger than steady errors such as the effect of recovery factor. In this paper, the origins of steady and unsteady measurement errors are described and evaluated. An analytical modeling of the transient convection/conduction problem is presented. A number of probe designs are described and evaluated at different Reynolds number. The dynamic response is tested in a hot jet apparatus that generates temperature steps, with jet velocities up to 150m/s. The influence of the length/diameter ratio, the type of support and the presence of a shield on the dynamic response are addressed. The unsteady behavior of a thermocouple probe can be replicated with a combination of first order systems, which defines the transfer function of the probe. The relevant parameters are found by using an optimization routine that fits the numerical system response to the experimental response. This numerical model can be reversed to perform a frequency compensation of the measured data.
Skip Nav Destination
ASME Turbo Expo 2002: Power for Land, Sea, and Air
June 3–6, 2002
Amsterdam, The Netherlands
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
0-7918-3607-X
PROCEEDINGS PAPER
Thermocouple Probes for Accurate Temperature Measurements in Short Duration Facilities
G. Paniagua,
G. Paniagua
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
R. De´nos,
R. De´nos
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
M. Oropesa
M. Oropesa
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Search for other works by this author on:
G. Paniagua
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
R. De´nos
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
M. Oropesa
von Karman Institute for Fluid Dynamics, Rhode Saint Gene`se, Belgium
Paper No:
GT2002-30043, pp. 209-217; 9 pages
Published Online:
February 4, 2009
Citation
Paniagua, G, De´nos, R, & Oropesa, M. "Thermocouple Probes for Accurate Temperature Measurements in Short Duration Facilities." Proceedings of the ASME Turbo Expo 2002: Power for Land, Sea, and Air. Volume 2: Turbo Expo 2002, Parts A and B. Amsterdam, The Netherlands. June 3–6, 2002. pp. 209-217. ASME. https://doi.org/10.1115/GT2002-30043
Download citation file:
59
Views
Related Proceedings Papers
Related Articles
Effect of Fouling on Temperature Measurement Error and a Solution
J. Heat Transfer (May,1998)
Modelling, Identification and Control of Thermal Deformation of Machine Tool Structures, Part 5: Experimental Verification
J. Manuf. Sci. Eng (August,1999)
Cryosurgery of Normal and Tumor Tissue in the Dorsal Skin Flap Chamber: Part I—Thermal Response
J Biomech Eng (August,2001)
Related Chapters
EVALUATION OF THERMAL PROBE COOLING EFFECT BASED ON PIPELINE PARALLEL OPTICAL CABLE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Completing the Picture
Air Engines: The History, Science, and Reality of the Perfect Engine
Graphical Methods for Control Systems
Introduction to Dynamics and Control in Mechanical Engineering Systems